Certified performance, documented per project

Every Neisen configuration is tested for air, water and wind-load performance to the standard of its market, and the report travels with the project.

01 · Test standards

Three standards, one window

The same system is tested to the method of the market it is sold into. The three cover China, Europe and North America.

China

GB/T 7106

The national test method for external windows and doors: air permeability, watertightness and wind-load resistance, each graded from 1 to 9.

  • Air permeability · grade
  • Watertightness · grade
  • Wind-load resistance · grade
Europe

EN 14351-1

The European product standard behind CE marking: air permeability to EN 1026, watertightness to EN 1027 and resistance to wind load to EN 12211, with thermal transmittance declared.

  • Air permeability · class
  • Watertightness · class
  • Wind load · class
  • Thermal transmittance · U-value
North America

NAFS

The North American Fenestration Standard (AAMA / WDMA / CSA 101 / I.S.2 / A440): a Performance Grade and Design Pressure for the whole assembly, tested for air, water and structural load; the basis of U.S. and Canadian specifications.

  • Performance Grade · PG
  • Design Pressure · DP
  • Air · water · structural
02 · Testing and certification partners

Independent laboratories, recognised worldwide

Intertek

Accredited testing and certification; NAFS and EN test programmes.

NAMI

National Accreditation & Management Institute: product certification for the North American market.

NFRC

National Fenestration Rating Council: energy ratings — U-factor, solar heat gain, visible transmittance.

CCIC

China Certification & Inspection Group: inspection and certification for export shipments.

03 · Management systems

Manufactured under ISO 9001, 14001 and 45001

Quality, environmental and occupational health and safety management systems certified at Zhejiang Baoye Curtain Wall, the company that engineers and manufactures Neisen.

Certificates and company honours
ISO 9001
Quality management
ISO 14001
Environmental management
ISO 45001
Occupational health and safety
04 · Your report

How to get the test report for your configuration

Performance depends on size, glazing and operation, so we state it per configuration rather than as one number for the series.

  1. 1

    Send the opening schedule

    Sizes, operation types, glazing and the market the project is in.

  2. 2

    We match or test

    An existing report covers the configuration, or the configuration is tested at an accredited laboratory.

  3. 3

    Report and specification text

    The test report plus specification clauses ready for the tender documents.

Reports are issued for the configuration tested; published performance tables for each series will follow as test programmes are completed.